01 | Passed | 46 | Improper Boxes for Use |
02 | Failed | 47 | Boxes Not Cut In |
03 | Inaccessible | 48 | Support Boxes Properly |
04 | Job not Ready | 49 | Boxes Not Grounded |
05 | Too Many to List | 50 | Boxes Damaged |
06 | Defects Not Corrected | 51 | Sheath Not in Box or Connector |
07 | Need Qualified Individual to Call | 52 | General Use Receptacle Spacing |
08 | Service | 53 | Kitchen Counter Top Receptacle Spacing |
09 | Grounding | 54 | Recpt. Not Equally Divided on Small Appliance Circuit |
10 | Bonding | 55 | GFCI Defect General |
11 | Incorrect Size or Type Wire | 56 | GFCI Kitchen |
12 | Equipment Securely Mounted | 57 | GFCI Bathroom |
13 | Identify Conductors | 58 | No Recpt. Adjacent to Basin |
14 | Circuit Overloaded | 59 | No Continuity on Receptacle |
15 | Grouping of Mains | 60 | Device Loose in Box |
16 | Multiwire Circuits on Same Phase | 61 | Reverse Polarity on Recpt. |
17 | Loose Connections | 62 | Need Extension Rings |
18 | Isolate Neutral in Sub Pnl | 63 | Ground Switch |
19 | Label Panel | 64 | Devices not Installed |
20 | Panel Blanks | 65 | AFCI Defect |
21 | Need KO Stopper | 66 | Fixture not Installed |
22 | Covers Missing | 67 | Fixture Location |
23 | Troughs Overloaded | 68 | Recessed Fixtures not Wired |
24 | Secure Backfed Breakers | 69 | Recessed Fixtures in Contact with Combustible Material |
25 | Improper Overcurrent Prot | 70 | Support Light Fixtures |
26 | Inter Mixing Diff Class Circ | 71 | Closet Fixture Clearance |
27 | Clearances-Article 110-26 | 72 | Fixture not Grounded |
28 | Separation Parallel Conduits | 73 | Install Smoke Detector(s) |
29 | Make Joints on Multi Wire Branch Circuit | 74 | Smoke Detector Location |
30 | Improper Wiring Method | 75 | Interlock Smoke Detectors |
31 | Cable Subject to Damage | 76 | Smoke Detector not Arc Fault |
32 | Support Cables | 77 | Install Blank Plate |
33 | Cables Damaged | 78 | No Disconnect on Equipment |
34 | Loose Joints | 79 | Equipment Not Wired |
35 | Free Conductor at Outlet Box | 80 | Need dedicated circuit to Equipment |
36 | Support Raceways | 81 | Line and Load Reversed |
37 | Need Stud Guards | 82 | Incorrect Wiring to Equip. |
38 | Cable Stapled too Close to Face of Stud | 83 | GDO Cord will not reach Receptacle |
39 | Raceways Overloaded | 84 | Cords |
40 | Terminate and Remove Unused Wire | 85 | Incorrect Wiring to Well |
41 | Improper Joints or Terminations | 86 | Incorrect Wiring to Sewer |
42 | Remove Temporary Wiring | 87 | Identify Disconnect |
43 | Circuit Shorted Out | 88 | Support of Pole |
44 | Ditches Not Deep Enough | 89 | Height of Pole |
45 | Boxes Overloaded | 90 | Ground Rod |